Login | DPI Staff queries on depositing or searching to era.daf.qld.gov.au

Loop-mediated isothermal amplification (LAMP) assays for detection of the New Guinea fruit fly Bactrocera trivialis (Drew) (Diptera: Tephritidae)

Share this record

Add to FacebookAdd to LinkedinAdd to XAdd to WechatAdd to Microsoft_teamsAdd to WhatsappAdd to Any

Export this record

View Altmetrics

Starkie, M. L., Fowler, E. V., Zhu, X., Agarwal, A., Rako, L., Schneider, I. C., Schutze, M. K., Royer, J. E., Gopurenko, D., Gillespie, P. and Blacket, M. J. (2022) Loop-mediated isothermal amplification (LAMP) assays for detection of the New Guinea fruit fly Bactrocera trivialis (Drew) (Diptera: Tephritidae). Scientific Reports, 12 (1). p. 12602. ISSN 2045-2322

[img]
Preview
PDF
2MB

Article Link: https://doi.org/10.1038/s41598-022-16901-0

Publisher URL: https://doi.org/10.1038/s41598-022-16901-0

Abstract

The cue-lure-responding New Guinea fruit fly, Bactrocera trivialis, poses a biosecurity risk to neighbouring countries, e.g., Australia. In trapping programs, lure caught flies are usually morphologically discriminated from non-target species; however, DNA barcoding can be used to confirm similar species where morphology is inconclusive, e.g., Bactrocera breviaculeus and B. rufofuscula. This can take days—and a laboratory—to resolve. A quicker, simpler, molecular diagnostic assay would facilitate a more rapid detection and potential incursion response. We developed LAMP assays targeting cytochrome c oxidase subunit I (COI) and Eukaryotic Translation Initiation Factor 3 Subunit L (EIF3L); both assays detected B. trivialis within 25 min. The BtrivCOI and BtrivEIF3L assay anneal derivatives were 82.7 ± 0.8 °C and 83.3 ± 1.3 °C, respectively, detecting down to 1 × 101 copies/µL and 1 × 103 copies/µL, respectively. Each assay amplified some non-targets from our test panel; however notably, BtrivCOI eliminated all morphologically similar non-targets, and combined, the assays eliminated all non-targets. Double-stranded DNA gBlocks were developed as positive controls; anneal derivatives for the COI and EIF3L gBlocks were 84.1 ± 0.7 °C and 85.8 ± 0.2 °C, respectively. We recommend the BtrivCOI assay for confirmation of suspect cue-lure-trapped B. trivialis, with BtrivEIF3L used for secondary confirmation when required.

Item Type:Article
Business groups:Biosecurity Queensland
Subjects:Science > Entomology
Plant culture > Fruit and fruit culture
Plant pests and diseases
Live Archive:03 Aug 2022 04:57
Last Modified:03 Aug 2022 04:57

Repository Staff Only: item control page

Downloads

Downloads per month over past year

View more statistics