Login | DPI Staff queries on depositing or searching to era.daf.qld.gov.au

Comparison of the q-fever complement fixation test and two commercial enzyme-linked immunosorbent assays for the detection of serum antibodies against coxiella burnetii (Q-fever) in ruminants: Recommendations for use of serological tests on imported animals in New Zealand

Share this record

Add to FacebookAdd to LinkedinAdd to XAdd to WechatAdd to Microsoft_teamsAdd to WhatsappAdd to Any

Export this record

View Altmetrics

Kittelberger, R., Mars, J., Wibberley, G., Sting, R., Henning, K., Horner, G.W., Garnett, K.M., Hannah, M.J., Jenner, J.A., Pigott, C.J. and O'Keefe, J.S. (2009) Comparison of the q-fever complement fixation test and two commercial enzyme-linked immunosorbent assays for the detection of serum antibodies against coxiella burnetii (Q-fever) in ruminants: Recommendations for use of serological tests on imported animals in New Zealand. New Zealand Veterinary Journal, 57 (5). pp. 262-268. ISSN 0048-0169

Full text not currently attached. Access may be available via the Publisher's website or OpenAccess link.

Article Link: https://doi.org/10.1080/00480169.2009.58619

Abstract

AIM: To make valid recommendations on the use of serological test methods for the detection of serum antibodies in ruminants against Coxiella burnetii (Q-fever), by comparing the performance of the complement fixation test (CFT) and two ELISA, and by identifying reasons for discrepancies between the test methods.

METHODS: A total of 73 serum samples from infected cattle, 69 from infected goats, and 100 samples from non-infected cattle and 57 samples from non-infected sheep, as well as 95 samples from infected cattle herds (mix of seropositive and seronegative samples), were tested using the CFT, the IDEXX ELISA (I-ELISA) and the Pourquier ELISA (P-ELISA). A mixed panel of 12 serum samples from sheep from inter-laboratory proficiency testing (proficiency panel) was also tested using the CFT and both ELISA, and further investigated using IgG- and IgM-specific ELISA.

RESULTS: Generally, the two commercial ELISA were more sensitive than the CFT for the detection of infected ruminants. Good agreement between ELISA for positive and negative results was found for samples from the infected herd, while results for the positive panels varied between the two ELISA. For the total of the positive serum panels, the I-ELISA detected 95% of samples as positive or suspicious, while the P-ELISA detected only 81%. In the P-ELISA, more samples were considered suspicious (18%) than in the I-ELISA (14%). All sera from noninfected sheep and cattle tested negative in the serological test methods employed, except for one positive sample from a sheep in the P-ELISA. Further investigation revealed that a CFT-positive but ELISA-negative result was due to high IgM and low IgG reactivity.

CONCLUSIONS: The two commercial ELISA were more sensitive than the CFT in all panels from infected ruminants. However, they could only detect IgG. The I-ELISA should be the serological test method of choice for cattle, sheep and goats for import testing of animals into New Zealand because it was more sensitive than the P-ELISA and was equally specific to the PELISA and the CFT. For other animal species, such as deer and camelids, the CFT should still be used since none of the ELISA has been evaluated for these species. This study has shown that the two commercial ELISA will detect the majority of infected ruminants but may miss animals that have not developed an IgG response.

Item Type:Article
Keywords:Q-fever, Coxiella burnetii, enzyme-linked, immunosorbent assay, ELISA, complement fixation test
Subjects:Veterinary medicine > Veterinary epidemiology. Epizootiology
Veterinary medicine > Diseases of special classes of animals > Cattle
Veterinary medicine > Diseases of special classes of animals > Sheep and goats